The Coxreels PC13-5012-4 is a spring rewind power cord reel from the PC Series, designed to keep electrical cord organized, retractable, and ready for use in service bays, maintenance shops, garages, workstations, warehouses, and industrial work areas. This model includes a 50 ft cord length and is rated for 20 amps at 115 volts, making it a mid-length, higher-amperage cord reel option for compatible electrical devices where the connected load, plug, receptacle, cord type, and power source match the reel rating.
The PC13-5012-4 helps reduce loose cord across floors, benches, and walk paths by allowing users to pull out the required length, lock it in place during operation, and retract it when the task is complete. Its spring rewind mechanism supports automatic cord return, while the adjustable guide arm allows wall, floor, vehicle, or overhead mounting when installed on a suitable surface for the application.
Type: Spring Rewind Power Cord Reel | Series: PC Series | Model: PC13-5012-4 | Cord Included: Yes | Cord Length: 50 ft | Amps: 20 | Volts: 115 | Rewind Type: Spring Rewind | Mounting: Wall, Floor, Vehicle, Overhead | Reel Style: Single Pedestal Power Cord Reel
Features:
- Spring driven power cord reel stores cord neatly between tasks, helping reduce loose electrical cord across floors, benches, walk paths, and service areas.
- 50 ft cord length provides more reach than shorter 35 ft configurations while maintaining controlled cord storage in busy work areas.
- 20 amp and 115 volt rating supports compatible electrical loads when the connected equipment, plug, receptacle, and power source match the reel rating.
- Compact single pedestal reel design helps conserve mounting space in shops, garages, service vehicles, maintenance areas, and production workstations.
- Adjustable guide arm supports wall, floor, vehicle, and overhead mounting positions to suit the reel location and cord payout direction.
- Multi-position lock ratchet mechanism secures the cord at the selected working length during use.
- Enclosed factory-tuned cartridge-style spring motor provides automatic cord return after the job is complete.
- Solid one-piece heavy gauge steel base and support post provide stable reel support for routine cord payout and rewind.
- 1" solid steel axle and lubricated precision bearings support smooth reel rotation during operation.
- CPC powder coat finish helps protect the reel structure in shop, service, and industrial work environments.
Made in USA: 
Applications:
- Maintenance shops and MRO departments where a retractable 115 volt cord reel helps keep electrical cord controlled between tasks.
- Automotive, fleet, and equipment service bays where 50 ft of cord reach supports compatible tools, lights, chargers, or electrical devices.
- Manufacturing, assembly, and repair workstations that need organized point-of-use power access across a moderate work area.
- Service trucks and mobile repair vehicles where retractable cord storage helps reduce loose cable during transport and field work.
- Garages, warehouses, and general industrial workspaces where controlled cord payout and automatic rewind help improve cord management around active work areas.
FAQs:
- Q: Does the Coxreels PC13-5012-4 include cord?
A: Yes. This model is listed as a power cord reel with a 50 ft cord length. - Q: What electrical rating does this reel have?
A: The PC13-5012-4 is rated for 20 amps at 115 volts. Always confirm that the connected equipment stays within the reels electrical rating before use. - Q: How is the PC13-5012-4 different from the PC13-3512-4?
A: Both models are rated for 20 amps at 115 volts, but the PC13-5012-4 provides 50 ft of cord length while the PC13-3512-4 provides 35 ft. - Q: How is the PC13-5012-4 different from the PC13-5016-4?
A: Both models provide 50 ft of cord length at 115 volts, but the PC13-5012-4 is rated for 20 amps while the PC13-5016-4 is rated for 10 amps. - Q: What does the spring rewind mechanism do?
A: The spring rewind mechanism retracts the cord back onto the reel after use, helping keep the cord organized and reducing loose cable across the floor. - Q: Can this reel be mounted overhead?
A: Yes. The adjustable guide arm supports overhead mounting as well as wall, floor, and vehicle mounting when the mounting surface and installation method are suitable for the reel and work environment. - Q: Is this reel compatible with every 115 volt device?
A: No. The connected device must be compatible with the reels 20 amp and 115 volt rating, and the plug, receptacle, cord type, and work environment must match the application requirements. - Q: When should I choose a 50 ft cord reel?
A: Choose a 50 ft cord reel when the power source is not immediately beside the work area and more reach is needed than a 35 ft reel provides. A longer reel may be preferred for wider bays or larger service zones. - Q: Why choose a 20 amp model instead of a lower-amperage cord reel?
A: A 20 amp model may be appropriate when compatible equipment requires a higher amperage rating than 10 amp or 13 amp models provide. The full electrical setup must still match the reel rating and installation requirements.
| CORD | SIZE INDEX |
|||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| SKU | ACCESSORY | INLET OUTLET |
AWG / NO COND. |
CORD FT. |
TYPE | VOLTS | AMPS | APRX. LBS. |
EZ-COIL SKU | |
|
FOR INDOOR USE ONLY!All models rated at 115 volts, 60 hz single phase only.
|
||||||||||
| PC13-3516-A† | Single Industrial Receptacle1 |
16 / 3 | 35 | SJO | 115 | 13 | 34 | - | 1 | |
| PC13-5016-A† | Single Industrial Receptacle1 |
16 / 3 | 50 | SJO | 115 | 13 | 36 | EZ-PC13-5016-A | 1 | |
| PC19-7516-A† | Single Industrial Receptacle1 |
16 / 3 | 75 | SJO | 115 | 13 | 60 | - | 3 | |
| PC24-0016-A† | Single Industrial Receptacle1 |
16 / 3 | 100 | SJO | 115 | 13 | 73 | EZ-PC24-0016-A | 4 | |
| PC13-3512-A† | Single Industrial Receptacle1 |
12 / 3 | 35 | SJO | 115 | 20 | 37 | - | 1 | |
| PC13-5012-A† | Single Industrial Receptacle1 |
12 / 3 | 50 | SJO | 115 | 20 | 40 | EZ-PC13-5012-A | 1 | |
| PC19-7512-A† | Single Industrial Receptacle1 |
12 / 3 | 75 | SJO | 115 | 20 | 67 | - | 3 | |
| PC24-0012-A† | Single Industrial Receptacle1 |
12 / 3 | 100 | SJO | 115 | 20 | 81 | EZ-PC24-0012-A | 4 | |
| PC13-3512-B† | Quad “4 Plug” Industrial Receptacle1 |
12 / 3 | 35 | SJO | 115 | 20 | 38 | - | 1 | |
| PC13-5012-B† | Quad “4 Plug” Industrial Receptacle1 |
12 / 3 | 50 | SJO | 115 | 20 | 41 | EZ-PC13-5012-B | 1 | |
| PC19-7512-B† | Quad “4 Plug” Industrial Receptacle1 |
12 / 3 | 75 | SJO | 115 | 20 | 68 | - | 3 | |
| PC24-0012-B† | Quad “4 Plug” Industrial Receptacle1 |
12 / 3 | 100 | SJO | 115 | 20 | 84 | EZ-PC24-0012-B | 4 | |
| PC13-3516-F† | Duplex G.F.C.I. Metal Industrial Receptacle1 |
16 / 3 | 35 | SJO | 115 | 13 | 36 | - | 1 | |
| PC13-5016-F† | Duplex G.F.C.I. Metal Industrial Receptacle1 |
16 / 3 | 50 | SJO | 115 | 13 | 38 | EZ-PC13-5016-F | 1 | |
| PC19-7516-F† | Duplex G.F.C.I. Metal Industrial Receptacle1 |
16 / 3 | 75 | SJO | 115 | 13 | 60 | - | 3 | |
| PC24-0016-F† | Duplex G.F.C.I. Metal Industrial Receptacle1 |
16 / 3 | 100 | SJO | 115 | 13 | 73 | EZ-PC24-0016-F | 4 | |
| PC13-3512-F† | Duplex G.F.C.I. Metal Industrial Receptacle1 |
12 / 3 | 35 | SJO | 115 | 20 | 39 | - | 1 | |
| PC13-5012-F† | Duplex G.F.C.I. Metal Industrial Receptacle1 |
12 / 3 | 50 | SJO | 115 | 20 | 42 | EZ-PC13-5012-F | 1 | |
| PC19-7512-F† | Duplex G.F.C.I. Metal Industrial Receptacle1 |
12 / 3 | 75 | SJO | 115 | 20 | 67 | - | 3 | |
| PC24-0012-F† | Duplex G.F.C.I. Metal Industrial Receptacle1 |
12 / 3 | 100 | SJO | 115 | 20 | 83 | EZ-PC24-0012-F | 4 | |
| PC19-7516-X | With Cord, Less Accessory |
16 / 3 | 75** | SJO | 115 | 13 | 60 | - | 3 | |
| PC24-0016-X | With Cord, Less Accessory |
16 / 3 | 100** | SJO | 115 | 13 | 71 | EZ-PC24-0016-X | 4 | |
| PC13-5012-X†† | With Cord, Less Accessory |
12 / 3 | 50** | SJO | 115 | 20 | 40 | EZ-PC13-5012-X | 1 | |
| PC19-7512-X | With Cord, Less Accessory |
12 / 3 | 75** | SJO | 115 | 20 | 66 | - | 3 | |
| PC24-0012-X | With Cord, Less Accessory |
12 / 3 | 100** | SJO | 115 | 20 | 81 | EZ-PC24-0012-X | 4 | |
| PC17-3510-X†† | With Cord, Less Accessory |
10 / 3 | 35** | SO | 115 | 30 | 62 | - | 2 | |
| PC17-5010-X†† | With Cord, Less Accessory |
10 / 3 | 50** | SO | 115 | 30 | 67 | - | 2 | |
| PC13-3516-4 | With Cord, Less Accessory |
16 / 4 | 35 | SJO | 115 | 10 | 34 | - | 1 | |
| PC13-5016-4 | With Cord, Less Accessory |
16 / 4 | 50 | SJO | 115 | 10 | 36 | - | 1 | |
| PC24-0016-4 | With Cord, Less Accessory |
16 / 4 | 100 | SJO | 115 | 10 | 74 | - | 4 | |
| PC13-3512-4 | With Cord, Less Accessory |
12 / 4 | 35 | SJO | 115 | 20 | 31 | - | 1 | |
| PC13-5012-4 | With Cord, Less Accessory |
12 / 4 | 50 | SJO | 115 | 20 | 40 | EZ-PC13-5012-4 | 1 | |
| PC24-0012-4 | With Cord, Less Accessory |
12 / 4 | 100 | SJO | 115 | 20 | 85 | - | 4 | |
| PC13L-5016†† | Less Cord, Less Accessory |
16 / 3 | 50* | SJO | 115 | 25 | 31 | EZ-PC13L-5016 | 1 | |
| PC19L-7516 | Less Cord, Less Accessory |
16 / 3 | 75 | SJO | 115 | 25 | 52 | - | 3 | |
| PC24L-0016 | Less Cord, Less Accessory |
16 / 3 | 100 | SJO | 115 | 25 | 62 | EZ-PC24L-0016 | 4 | |
| PC13L-5012†† | Less Cord, Less Accessory |
12 / 3 | 50 | SJO | 115 | 25 | 29 | EZ-PC13L-5012 | 1 | |
| PC19L-7512 | Less Cord, Less Accessory |
12 / 3 | 75 | SJO | 115 | 25 | 53 | - | 3 | |
| PC24L-0012 | Less Cord, Less Accessory |
12 / 3 | 100 | SJO | 115 | 25 | 64 | EZ-PC24L-0012 | 4 | |
| PC17L-5010†† | Less Cord, Less Accessory |
10 / 3 | - | - | 115 | 30 | 49 | - | 2 | |
| PC13L-5016-4 | Less Cord, Less Accessory |
16 / 4 | 50 | SJO | 115 | 25 | 31 | - | 1 | |
| PC24L-0016-4 | Less Cord, Less Accessory |
16 / 4 | 100 | SJO | 115 | 25 | 62 | - | 4 | |
| PC13L-5012-4 | Less Cord, Less Accessory |
12 / 4 | 50 | SJO | 115 | 25 | 29 | - | 1 | |
| PC24L-0012-4 | Less Cord, Less Accessory |
12 / 4 | 100 | SJO | 115 | 25 | 64 | - | 4 | |